Recorder Features
■ With advanced design and technology, the recorder can work stably,
dependable and durable.
■ Be provided with the capability of anti-jamming and shock-pro.
■ Small volume with OLED screen. The resolution is 160*128.
■ Be provided with functions of waveform preview, record review and event
marking.
■ Accurate record of the start time of the data sampled owing to the real time
clock of itself.
■ Avoid damage owing to the repeating inserting and pulling out by using the
inbuilt TF card to storage the data.
■ The maximum capability can be 2GB, so the original data can be saved perfectly
by no compression.
■ The average review time of single case can be less than 40 seconds by using
interface of USB 2.0.
■ Record waveform details inextenso by the design of high precision and sampling
frequency.
■ Record the state of pacemaker exactly by higher sampling frequency.
■ International standard of 12 leads. Record 24-hour DECG with the same
standard of the ECG.
The features of software
■ Quick and accurate analysis system.
■ With 12 leads synchro analysis , QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular
premature beat module, long interval module, atrial flutter module, atrial
fibrillation module etc. and multiplicate User-defined templates could almost
identify every kind of pathologic waveforms.
■ Optional main channel.
■ Agile and exact "Atrial Fibrillation" analysis.
■ The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 12-leads ECG can be reviewed at any time with the
function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short
ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the
heart muscle, the physician can judge a disease or disorder of the heart muscle
generally.
■ "Sleep breath pause syndrome analysis", the physician could print sleep
asphyxia analysis report and diagnose.
■ "HRT" analysis, when the adjustable function is natural, this transitory change
will be represented by the form of HRT immediately.
15."T Wave alternation" analysis is a important index on judging and preventing
Arrhythmia .
■ The report has more reference value with the functions of VCG, VLP, TVCG and
QTD analysis.
Standard
Number of channels: 12 channels;
Sampling rate:10000Hz;
Sampling accuracy:12bit;
Recording time : 24 h;
Power: 2 batteries in size 5;
Interface: USB2.0;
Scale voltage:1mV±5%;
Standard Sensitivity:10mm/mV±5%;
Noise level:≤30μV;
CMRR:≥60dB;
Feathers of low frequency : Time constant>3.2s;
Scan speed:25mm/s±5%;
Enduring polarization voltage:±300mV;
Least measure signal : 50 µV p-p;
Product safety type : Type B (Internally powered);
Size:111mm(L)*60mm(W)*25mm(H);
Net Weight: 102g (Without battery).